Last updated: 23 ธ.ค. 2568 | 17 จำนวนผู้เข้าชม |
Description
The S330 / S331 Data Logger and Display provides a universal solution for displaying and recording all relevant parameter of a compressed air system. This includes flow, dew point, pressure, temperature, power consumption, compressor status, and so on. The device offers a powerful yet cost-efficient data logger and display solution for optimal and reliable management and monitoring of your compressed air system.
S331 Compact Version: Central Unit for Your System
The Compact Version of the S331 Data Logger is used to gather and collect measurement data of various field devices. It acts as the central unit where all measurement data is safely stored and visualized. The digital communication outputs expand the S331 to not only be a display and data logger, but also a gateway to connect to IIoT services and to modern software solutions.
S331 Flex Version: More Power and Larger Internal Wiring Space
The S331 Flex Version, a size upgrade from the S331 Compact Version, features an improved hardware design for greater stability and reliability. In addition, the larger housing offers more space for internal wiring and more power for connected sensors. It retains all the technical specifications of the S331 Compact Version and acts as a central data hub, efficiently collecting and organizing measurement data from multiple field devices.
S330: Display Solution
The S330 is a simple and easy-to-install display device with a high resolution 5” graphic display. This allows an easy operation where details are much sharper shown compared to many of the smaller low-resolution displays.
SIGNAL INTERFACE & SUPPLY
Data logger
Storage
Internal, up to 100 million values
Sampling rate
Optional >=1s, Max 59 mm:59 ss
Input signals
Digital input
2 x SDI sensors 16 x RS-485 Modbus RTU Sensors 2 x 0 ... 20 mA / 4 ... 20 mA / 0 ... 10 V
Analog input
2 x 0/4 ... 20 mA; 2 x 0 ... 10 V;
2 x pulse
Pulse input
100 Hz maximum; 28 V, 10 Ma
Output signals
Analog / Pulse output
4 ... 20 mA signal and pulse signal of sensors can be looped through the display by using the connection board
Alarm output
2 Relais, 230 VAC, 3 A, NC
Field bus Interface
Protocol
Modbus/TCP (Ethernet), Modbus/RTU ( RS 485)
Electrical data
Power supply
100 ... 240 VAC, 20 VA (option, A1663) 18 ... 30 VDC, 20 W (option, A1664)
Sensor supply
24 V, 10 W
Data interface
Connection
Modbus/TCP (Ethernet), Modbus/RTU ( RS 485), USB
23 ธ.ค. 2568
23 ธ.ค. 2568
23 ธ.ค. 2568
23 ธ.ค. 2568